Re the BSM scopes: I am wondering what the upper (bright) limits are for Ic imaging. For example, could I reasonably image a variable if its Ic magnitude at the time was Ic mag 3-4?
Thanks, Ed
HQA
Affiliation
American Association of Variable Star Observers (AAVSO)
The BSM systems are spec'd to be able to image 2nd magnitude objects. That said, 2nd magnitude requires about 50-100 images per filter to reduce scintillation. At mag 3-4, you need about 10 images per filter to reduce scintillation, and then stack and measure. We did eps Aur in 2009-2020 without problem, so you should be safe at Ic=3-4.
Arne
or to post comments
Ed__Wiley_WEY
Affiliation
American Association of Variable Star Observers (AAVSO)
Hi Ed,
The BSM systems are spec'd to be able to image 2nd magnitude objects. That said, 2nd magnitude requires about 50-100 images per filter to reduce scintillation. At mag 3-4, you need about 10 images per filter to reduce scintillation, and then stack and measure. We did eps Aur in 2009-2020 without problem, so you should be safe at Ic=3-4.
Arne
Many thanks, Arne, just the information I needed.